4.1 Cooling Installation Introduction

Reference Documents & Drawings:

90719 – Seakeeper 10 Cable Block Diagram

90833 – Seakeeper 10 Cooling Water Schematic

30322 – Seakeeper DC Seawater Pump Assembly

TB-90191 – Seawater Cooling Pump Recommendations


Figure 29Seakeeper 10 Cooling Components

The Seakeeper 10 is shipped with the cooling circuit filled and ready for use (See Figure 29). To cool the closed-loop cooling circuit on the unit, it requires a connection to a raw water pump, referred to as the seawater pump. Under all vessel operating conditions, the required seawater flow through the Seakeeper 10 heat exchanger is between 4.5 – 6 GPM (17 – 22.7 LPM). Prior to operation, the glycol level must be confirmed.

Seakeeper offers a compatible self-priming DC Seawater Pump (P/N 30322) that is pre-wired for the Seakeeper 10 installation and covered under the standard Seakeeper Warranty. See Drawing No. 30322, Jabsco Seawater Pump Assembly for details and the Seakeeper Options and Accessories Price List for pricing information.