Seakeeper 1 Operation Manual (90520-3); S/N 1-243-0875 to Current
4.3 12 VDC High Current Failure
If the 12 VDC high current is disconnected during operation, the Seakeeper application will go blank, ConnectBox lights will power down, flywheel speed will decrease, and the Seakeeper 1 will lock to prevent precession (no stabilization).
- Verify the boat’s overcurrent protection supplying +12 VDC high current has not tripped nor blown.
- When the +12 VDC high current is restored, the Seakeeper App powers up the display. The start-up screen appears, followed by the Home Screen. The ConnectBox illuminates.
- Press POWER button. The progress bar will appear and indicate flywheel speed. When the flywheel is at minimum operating speed, the STABILIZE button will appear so stabilization can be turned on. Depending on the flywheel’s speed when the +12 VDC high current is turned back on, this may take up to 15 minutes.